Chapter-01
(Concepts of switch gear and protection)
-Asiqur Rahman Milon,EETE-DIU,EEE-IEB(Con)
#What is switch Gear?
-In an electric power system switch gear is the
combination of electrical disconnected switches,fuses or circuit breakers used
to control,protect,and isolate electric equipements.Switch gear are used both
to de-energize equipement to allow work to be done or to clear faults
downstream.
#What are the main
component of switch gear?
- The main component of switch
gear are-
1)ACB(Air circuit breaker)
2)MCCB(Moulded case
circuit breaker)
3)Contactor
4)Relay
5)SPP
6)Capacitor
7)Starter
8)Isolator
9)MCB(Miniature circuit
breaker)
10)ELCB(Earth liakage
circuit breaker)
11)Changeover circuit
1) ACB(Air circuit breaker)- Air circuit breaker
is the primary protecting device of any switch gear.Any high power consuming
device such as panel board,power is distributed through ACB.This device cuts
the main circuit during earth fault,under voltage,and short circuits due to which
circuits connect through it are prevented from getting fail or damage.
Air circuit breaker is 3-pole or
4-pole.It ranges from 630amp to 10,000Amp.
2) MCCB(Moulded case circuit breaker)-Moulded
case circuit breaker is used to protect high load current devices from fault
overloading.Tripping mechanism in MCCB is thermal based,microprocessor based or
electronic based.
MCCB is 3-pole or
4-pole.
3) Contactor- Contactor is the most demanding
component of switch gear.This is an electrically operated switch.Inside
contactor there is an electomachanical system connected to the coil.It works on
the predefined supply being provided to the coil.
4) Relay-Relay is a switching device which is
electromechanically or electronically controlled to open or close the
relay.Relay are different types such as thermal relay,CT operated relay,solid
state relay,hybrid relay,electromechanical relay and electronic relay.
5) SPP (single phase preventer)-Motor wiring or
circuit may get damage due to failure of any of the phase in 3-phase motor.SPP
detects fault in 3 phase and blocks current in case of failure of any phase.
6) Capacitor-To maintain power factor capacitor
is use.Capacitor is generally air cooled or water cooled which is dry
type,MPP9metalized polypropylene)type and APP(all polypropylene)type.
7) Stater- DOL(Direct online starter) means
DOL.It consists of contactor and relay.Star Delta starter comprises of 3
contactor.1 timer and 1 relay.In any circuit if the current increases from a
predefined limit,the relay in starter gets trip hence blocks the flow of
current through the contactor thus prevents the motor from damaging.
8) Isolator-To operate a circuit manually
(ON/OFF),isolate is use.Isolator does not contain any protection or tripping
device. It’s operating system is manually
independent,quick make and quick break.
9) MCB (Miniature circuit breaker)-Miniature
circuit breaker is an electromechanical device which protects low electrical
circuits from overcurrent.MCB has tripping mechanism which can be reset
easily.MCB is 1 pole,2-pole,3-pole and 4-pole.
10) ELCB-Earth liakage circuit breaker is a
safety device thst protects circuits from fault and earthing and human from
electric shock.
11) MPCB(Motor protection circuit breaker)
#What are the essential
feature/characteristics of switch gear ?
- The essential
feature/characteristics of switch gear are-
1. Complete reliability: With the continued trend
of interconnection and the increasing capacity of generating stations, the need
for a reliable switchgear has become of paramount importance. This is not
surprising because switchgear is added to the power system to improve the reliability.
When fault occurs on any part of the power system, the switchgear must operate
to isolate the faulty section from the remainder circuit.
2. Absolutely certain discrimination: When
fault occurs on any section of the power system, the switchgear must be able to
discriminate between the faulty section and the healthy section. It should isolate
the faulty section from the system without affecting the healthy section. This
will ensure continuity of supply.
3. Quick operation: When fault occurs on any
part of the power system, the switchgear must operate quickly so that no damage
is done to generators, transformers and other equipment by the short-circuit
currents. If fault is not cleared by switchgear quickly, it is likely to spread
into healthy parts, thus endangering complete shut down of the system
4. Provision for manual control: A
switchgear must have provision for manual control. In case the electrical (or
electronics) control fails, the necessary operation can be carried out through
manual control.
5. Slecctivity-Swich gear must
have discrimination power between used protective gear and device.It find out
in system which part has fault that fault part need to isolate.
6. Sensitivity-If over current
flow in a system then need to isolate the system then is happen when switch
gear has sensitivity power.
7. High speed-Switch gear need
to take swift action as early as possible cause if it works early then device
don’t damage. Device longibility is high.
8. Stability-After protection
that fault then need to again start work with previous capacity.
9. Simplicity-Protective gear
and device structure and architecture must be simple.
#What
is the classification of switch gear?
- The classification
of switch gear is-
Switchgear can
be classified on the basis of voltage level in to the following
2. Medium
voltage (MV) Switchgear
3. High
voltage (HV) Switchgear
1. Low Voltage Switchgear
Generally electrical
switchgear rated upto 1 kV is termed as low voltage switchgear.
The term LV Switchgear includes
low voltage circuit breakers, switches, off load electrical isolators, HRC
fuses, earth leakage circuit breaker, miniature circuit breakers (MCB) and
molded case circuit breakers (MCCB) etc i.e. all the accessories required to
protect the LV system.
The most common use of LV switchgear is in LV distribution board.
The most common use of LV switchgear is in LV distribution board.
2. Medium Voltage
Switchgear
From 3 kV to 36 kV switchgear
system is categorized as medium voltage switchgear or MV switchgear.
These switchgears are of many types.
They may metal enclosed indoor type, metal enclosed outdoor type, outdoor type
without metal enclosure, etc. The interruption medium of this switchgear may be
oil, SF and vacuum.
The main requirement of MV
power network is to interrupt current during faulty condition irrespective of
what type of CB is used in the MV switchgear system. Although it may be capable
of functioning in other conditions also.
A medium voltage switchgear,
should be capable of,
1. Normal
ON/OFF switching operation.
2. Short
circuit current interruption.
3. Switching
of capacitive currents.
4. Switching
of inductive currents.
5. Some
special application.
3. High Voltage
Switchgear
The power system deals with
voltage above 36kV, is referred as high voltage.
As the voltage level is high the
arcing produced during switching operation is also very high. So, special care
to be taken during designing of high voltage switchgear.
High voltage circuit breaker,
is the main component of HV switchgear, hence high voltage circuit breaker
should have special features for safe and reliable operation.
Faulty tripping and switching
operation of high voltage circuit are very rear. Most of the time these circuit
breakers remain, at ON condition, and may be operated after a long period of
time. So CBs must be reliable enough to ensure safe operation, as when
required.
By using switch gear is two types-
1) Indoor
2) Outdoor